6.3 Steel Plate Shears
6.3.1 Installation of crop shears and cut-to-length shears shall be in accordance with the following requirements:
1 Take the centerline of mill unit as a reference to measure the centerlines of left and right housings.
2 Measure the verticality of inner side of the left and right mill housings.
3 Measure the elevation and levelness on the cutting table.
4 The cutting table,front plate and connecting beam shall be assembled tightly and securely with the left and right mill housings,and checked with feeler gauge.
5 The assembly clearance for the upper and lower cutting edges shall meet the requirements of design documents.
6.3.2 Allowable deviation for crop shear and cut-to-length shear installation shall be in accordance with those specified in Table 6.3.2.
Table 6.3.2 Allowable deviation for crop shears and cut-to-length shears installation
6.3.3 Installation of double-sides trimming shear shall be in accordance with the following requirements:
1 Take the centerline of mill unit as a reference to measure the longitudinal centerline of double-sides trimming shear;Take the mill train centerline as a reference to measure the horizontal centerline of double-sides trimming shear.
2 The verticality of fixed shear housing of double-sides shears shall be measured and meet the requirements of item 3 of article 6.3.1 in this code.
3 Measure the elevation and levelness of the cutting table.
4 Take the centerline of fixed shear housing as a reference to measure the longitudinal centerline of guide rail of movable shear housing.
5 The height difference between the movable shear guide rail surface and the cutting table of fixed shear shall meet the requirements of design documents.
6 Measure the levelness of the movable shear guide rail and the parallelism of two guide rails.
7 Take the centerline of mill unit as a reference to measure the parallelism of lower cutting edge of fixed shear and movable shear relative to the reference.
6.3.4 Allowable deviation for double-sides trimming shear installation shall be in accordance with those specified in Table 6.3.4.
Table 6.3.4 Allowable deviation for double-sides trimming shear installation
Table 6.3.4(Continued)