GB 50825-2013 钢铁厂加热炉工程质量验收规范 (英文版)
上QQ阅读APP看本书,新人免费读10天
设备和账号都新为新人

6.2 Refractory

6.2.1 Site acceptance of refractory materials of the reheating furnace shall comply with the following requirements:

1 The alumina brick shall comply with the requirements in current national standard GB/T 2988 High Alumina Bricks.

2 The clay brick shall comply with the requirements in current professional standard YB/T 5106 Fireclay Bricks.

3 The light clay brick shall comply with the requirements in current national standard GB/T 3994 Fireclay Insulation Bricks.

4 The magnesite brick shall comply with the requirements in current national standard GB/T 2275 Magnesite Bricks and Magnesium-alumina Bricks.

5 The alumina Insulation Brick shall comply with the requirements in current national standard GB/T 3995 Shaped Insulating Refractory Products-High Alumina Bricks.

6 The size and appearance of the red brick shall comply with the requirements in current national standard GB 5101 Fired Common Bricks.

Check methods of Items 1 to 6 above:Checking the quality documents,sampling inspection upon doubt(if any)and the third party inspection.

Sample size:Sampling according to the requirements in current national standard GB/T 10325 Shaped Refractory Products-Rule of AcceptanceSampling and Inspection.

7 The size and appearance of the anchoring brick for reheating furnace shall comply with the requirements in current national standard GB/T 2988 High Alumina Bricks,and the performance of such brick shall comply with the requirements in current national standard GB/T 2988 High Alumina Bricks,moreover,its rupture strength after 3h sintering at 1350℃shall not be less than 8MPa.

Check method:Checking the quality documenst,on-site sampling inspection and the third party inspection.

Sample size:Sampling according to the requirements in current national standard GB/T 10325 Shaped Refractory Products-Rule of AcceptanceSampling and Inspection.

6.2.2 The site acceptance of castable refractory for reheating furnace shall comply with the requirements in current professional standard YB/T 5083 Dense Fireclay and High Alumina Castable Refractories.

Check method:Checking the quality documents,on-site sampling inspection and the third party inspection.

Sample size:Sampling according to the requirements in current national standard GB/T 17617 Refractory Products-Sampling of Raw Materials and Unshaped Products.

6.2.3 The site acceptance of plastic materials for reheating furnace shall comply with the requirements in current professional standard YB/T 5115 Fireclay and High Alumina Plastic Refractories.